{"opportunityId":"opp-maple-grove-school","warning":"AutoQuotes and CRM opportunity integrations are not connected. Records shown are read-only demonstration opportunities for workflow validation.","readOnly":true,"report":{"score":75,"label":"Good","categories":["Cooking","Refrigeration"],"equipment":[{"id":"mg-cook-1","category":"Cooking","description":"Cafeteria cooking line","manufacturer":"Vulcan","quantity":1,"includedCheckIds":["cook-utilities","cook-hood","cook-fire","cook-gas-kit","cook-casters"]},{"id":"mg-ref-1","category":"Refrigeration","description":"Serving-line refrigerated base","manufacturer":"Delfield","quantity":2,"includedCheckIds":["ref-electrical","ref-clearance","ref-ambient","ref-door"]}],"findings":[{"id":"cook-utilities","label":"Gas or electrical service verified","type":"Required","recommendationCategory":"Installation","rationale":"Capacity, voltage, phase, gas type and pressure must match the equipment.","omissionRisk":"Startup failure or costly utility changes.","category":"Cooking","equipmentId":"mg-cook-1","equipmentDescription":"Cafeteria cooking line","status":"Complete","confidence":97},{"id":"cook-hood","label":"Ventilation compatibility","type":"Required","recommendationCategory":"Safety","rationale":"Heat, grease and smoke loads must fit the hood design.","omissionRisk":"Code concern, poor capture or unsafe operation.","category":"Cooking","equipmentId":"mg-cook-1","equipmentDescription":"Cafeteria cooking line","status":"Complete","confidence":97},{"id":"cook-fire","label":"Fire suppression coverage","type":"Required","recommendationCategory":"Safety","rationale":"Protected appliances must align with the suppression layout.","omissionRisk":"Inspection failure or unsafe operation.","category":"Cooking","equipmentId":"mg-cook-1","equipmentDescription":"Cafeteria cooking line","status":"Complete","confidence":97},{"id":"cook-gas-kit","label":"Gas hose, restraint and quick disconnect","type":"Required","recommendationCategory":"Installation","rationale":"Movable gas appliances require a suitable connection package.","omissionRisk":"Incomplete installation or safety concern.","estimatedGpOpportunity":850,"category":"Cooking","equipmentId":"mg-cook-1","equipmentDescription":"Cafeteria cooking line","status":"Complete","confidence":97},{"id":"cook-casters","label":"Casters or equipment stand","type":"Recommended","recommendationCategory":"Installation","rationale":"Mobility and elevation should support cleaning and workflow.","omissionRisk":"Cleaning difficulty and incomplete package.","estimatedGpOpportunity":700,"category":"Cooking","equipmentId":"mg-cook-1","equipmentDescription":"Cafeteria cooking line","status":"Complete","confidence":89},{"id":"cook-startup","label":"Startup and calibration","type":"Recommended","recommendationCategory":"Service","rationale":"Calibration and combustion checks support safe, consistent operation.","omissionRisk":"Performance complaints and delayed issue discovery.","estimatedGpOpportunity":950,"category":"Cooking","equipmentId":"mg-cook-1","equipmentDescription":"Cafeteria cooking line","status":"Review","confidence":89},{"id":"cook-pm","label":"Preventative maintenance","type":"Recommended","recommendationCategory":"Maintenance","rationale":"Periodic inspection protects burners, controls and safety devices.","omissionRisk":"Higher downtime and missed service revenue.","estimatedGpOpportunity":1800,"serviceIntervalMonths":6,"category":"Cooking","equipmentId":"mg-cook-1","equipmentDescription":"Cafeteria cooking line","status":"Review","confidence":89},{"id":"ref-electrical","label":"Dedicated electrical service","type":"Required","recommendationCategory":"Installation","rationale":"Correct voltage and dedicated circuits support reliable operation.","omissionRisk":"Nuisance trips, startup delay or equipment damage.","category":"Refrigeration","equipmentId":"mg-ref-1","equipmentDescription":"Serving-line refrigerated base","status":"Complete","confidence":97},{"id":"ref-clearance","label":"Condenser airflow and clearance","type":"Required","recommendationCategory":"Performance","rationale":"Condensers require airflow to reject heat efficiently.","omissionRisk":"High head pressure, energy use and premature failure.","category":"Refrigeration","equipmentId":"mg-ref-1","equipmentDescription":"Serving-line refrigerated base","status":"Complete","confidence":97},{"id":"ref-ambient","label":"Ambient temperature verified","type":"Required","recommendationCategory":"Performance","rationale":"Hot kitchens and confined spaces can exceed equipment ratings.","omissionRisk":"Temperature failure and compressor stress.","category":"Refrigeration","equipmentId":"mg-ref-1","equipmentDescription":"Serving-line refrigerated base","status":"Complete","confidence":97},{"id":"ref-door","label":"Door swing and access verified","type":"Required","recommendationCategory":"Installation","rationale":"Door orientation and delivery access must suit the site.","omissionRisk":"Workflow conflict or delivery failure.","category":"Refrigeration","equipmentId":"mg-ref-1","equipmentDescription":"Serving-line refrigerated base","status":"Complete","confidence":97},{"id":"ref-casters","label":"Casters or seismic restraints","type":"Recommended","recommendationCategory":"Safety","rationale":"Mobility or restraint requirements should match cleaning and code needs.","omissionRisk":"Cleaning difficulty or compliance issue.","estimatedGpOpportunity":700,"category":"Refrigeration","equipmentId":"mg-ref-1","equipmentDescription":"Serving-line refrigerated base","status":"Review","confidence":89},{"id":"ref-shelving","label":"Additional shelving and pan slides","type":"Recommended","recommendationCategory":"Margin","rationale":"Storage accessories improve capacity and fit the customer workflow.","omissionRisk":"Reduced usable capacity.","estimatedGpOpportunity":900,"category":"Refrigeration","equipmentId":"mg-ref-1","equipmentDescription":"Serving-line refrigerated base","status":"Review","confidence":89},{"id":"ref-pm","label":"Condenser maintenance plan","type":"Recommended","recommendationCategory":"Maintenance","rationale":"Coil cleaning protects efficiency and compressor life.","omissionRisk":"Higher energy use and avoidable failures.","estimatedGpOpportunity":1800,"serviceIntervalMonths":3,"category":"Refrigeration","equipmentId":"mg-ref-1","equipmentDescription":"Serving-line refrigerated base","status":"Review","confidence":89}],"requiredComplete":8,"requiredTotal":8,"recommendedComplete":1,"recommendedTotal":6,"potentialGp":6150,"recurringRevenueOpportunities":["Preventative maintenance · every 6 months","Condenser maintenance plan · every 3 months"],"lifecycleGuidance":[{"category":"Cooking","guidance":"Typical planning range: 8–15 years, subject to use, maintenance and operating conditions."},{"category":"Refrigeration","guidance":"Typical planning range: 8–15 years, subject to use, maintenance and operating conditions."}],"summary":"All required equipment dependencies represented in the demonstration package are complete; recommended revenue and lifecycle items remain available.","assumptions":["Knowledge results are based on category-level DensonOS demonstration rules, not manufacturer submittals.","Local code, manufacturer instructions, site utilities and field conditions must be independently verified.","Potential gross-profit values are modeled opportunities and are not guaranteed financial outcomes.","No quote, price, AutoQuotes, Shopify or Cin7 record is modified by this analysis."]}}